Two Port 10/100 Managed Ethernet Switch with
Datasheet
14.5.2.9Port x MAC Receive 1024 to Max Byte Count Register (MAC_RX_1024_TO_MAX_CNT_x)
Register #: | Port0: 0416h | Size: | 32 bits | |
| Port1: | 0816h |
|
|
| Port2: | 0C16h |
|
|
This register provides a counter of received packets between the size of 1024 to the maximum allowable number bytes. The counter is cleared upon being read.
BITS |
| DESCRIPTION | TYPE | DEFAULT |
|
|
|
| |
31:0 | RX 1024 to Max Bytes | RC | 00000000h | |
| Count of packets (including bad packets) that have between 1024 and the |
|
| |
| maximum allowable number of bytes. The max number of bytes is 1518 for |
|
| |
| untagged packets and 1522 for tagged packets. If Jumbo2K (bit 3) is set in |
|
| |
| the Port x MAC Receive Configuration Register (MAC_RX_CFG_x), the max |
|
| |
| number of bytes is 2048. |
|
| |
| Note: | This counter will stop at its maximum value of FFFF_FFFFh. |
|
|
|
| Minimum rollover time at 100Mbps is approximately 5979 hours. |
|
|
|
|
|
|
|
Note: A bad packet is defined as a packet that has an FCS or Symbol error. For this counter, a packet with the maximum number of bytes that is not an integral number of bytes (e.g. a 1518 1/2 byte packet) is counted.
Revision 1.4 | 332 | SMSC LAN9311/LAN9311i |