Functions 9000-DVS 1 Chapter

Output signal settings (Output)

Output Assign: Assign the signals output from the Output ports.

Video Clip: Adjust the clip levels (White Clip, Dark Clip, and Chroma Clip) for the output signals from each of the Output ports.

V Blank: Adjust the vertical blanking width for the output signals from each of the Output ports. The setting is the number of scan lines from the reference blanking position of field 1 for the particular format which should be masked.

Through Mode: Enable or disable through mode.

Safe Title: Enable or disable safe title, and carry out settings for box 1 and 2 and cross.

Ref. Output Phase: Set the reference output mode and phase adjustment.

Settings relating to video switching (Transition)

Transition Preview: Specify the operating mode for transition preview for each of the M/E and P/P banks.

Key Transition: Specify the operating mode for independent key transitions.

Bus Toggle: Switch the bus toggle for each of the M/E and P/P banks on or off.

Split Fader: When the bus toggle is off, the split fader settings are enabled. For each of the M/E and P/P banks, select enable or disable.

Fade Curve: Set the relationship when carrying out a transition, between the fader lever position and the advancement state of the transition.

Key, wipe and frame memory settings (Key/Wipe/FM)

Key Memory: Set the key memory operating mode for each of the M/E and P/P banks.

Video Proc Memory: Enable or disable video process memory.

Show Key: Enable or disable show key for edit preview, M/E and P/P Pvw/ K-Pvw.

DSK Auto Drop: Specify a DSK to be turned off automatically when a cross-point button on the P/P program bus is pressed.

Key Priority: Set the key priority operating mode for each of the M/E and P/P banks. In DSK mode, the key priority is fixed.

Xpt Hold mode: Set the operating mode for the cross-point hold button provided on the key bus for each of the M/E and P/P banks.

Pattern Limit Transition: Set the operating mode when the pattern limit is released for each of the M/E and P/P banks.

Wipe Edge Default: Adjust the wipe edge softness for each of the M/E and P/P banks.

FM Auto Store: Switch on or off the function to automatically attach a name and save in frame memory.

130 Setup