Panel Control and Menus 2 Chapter
The number of valid buttons depends on the number of DME processor channels installed.
Note
In the
When the [DEV] button is selected: This enables the VTR operation mode in the device control block. In this state, the [M/E 1] and [M/E 2] buttons function as the device 1 and device 2 allocation buttons.
To exit from this mode, press the [DEV] button again, turning it off.
When the [RUN CTRL] button is selected: This enables the effect run control mode in the device control block.
The functions of the operation buttons, trackball, and
bOperation buttons
When the positioner operation mode is enabled
K1 CB1: Press this button to enable wipe pattern position setting for key 1 (DSK1).
When the [USER] button is selected, pattern position setting for color background 1 is enabled.
K2 CB2: Press this button to enable wipe pattern position setting for key 2 (DSK2).
When the [USER] button is selected, pattern position setting is enabled for color background 2.
K3 FM1: Press this button to enable wipe pattern position setting for key 3 (DSK3).
When the [USER] button is selected,
pattern position setting is enabled for frame memory 1.
K4 FM2: Press this button to enable wipe pattern position setting for key 4 (DSK4).
When the [USER] button is selected, pattern position setting is enabled for frame memory 2.
MAIN: Press this button to enable main wipe pattern position setting for normal transitions.
SUB: Press this button to enable sub wipe pattern position setting for normal transitions.
Among the [K1 CB1] button, [K2 CB2] button, [K3 FM1] button, [K4 FM2] button, [MAIN] button, and [SUB] button, you can make a multiple selection.
POS: Press this button to enable pattern movement in the
When the [USER] button is selected, this enables the trackball to move the pattern in the
X, Y: These restrict the axes affected by the trackball and
Z:When the [USER] button is selected, this restricts the axes affected by the trackball and
CTR (center): When this button is pressed, the pattern position returns to the center. When the [USER] button is selected, the pattern size also returns to 50.00.
SHIFT/CLR WORK BUFR: These are not used in positioner operation mode.
148 Names and Functions of Parts of the Control Panel