Keys 4 Chapter

2 In the <DME Select> group, select the DME channel (DME1 to DME8) to be used.

The colors with which [DME1] to [DME8] are lit show the key assignment status.

Lit green: The DME currently being monitored

Lit amber: DME assigned to KEY

Off: Unassigned DME

In the DVS-9000 system, the [DME5] to [DME8] buttons are disabled.

3 Press [Monitor Set].

This assigns the selected DME output to DME MON V and DME MON K.

Blink Function

With the blink function, you can obtain the following effects.

Key blink: The key is alternately inserted and deleted at regular intervals. You can set the period of blinking, and the proportion of each cycle for which the key is inserted.

Edge blink: The key fill and key edge fill signals are interchanged at regular intervals. You can set the period of blinking, and the proportion of each cycle for which the original state holds.

Using the blink function

For example, to make the required settings for key 1 on the M/E-1 bank, use the following procedure.

1 In the M/E-1>Key1 menu, select HF6 ‘Transition.’

The Transition menu appears.

2 In the <Blink> group, select [Key Blink] or [Edge Blink] to set it on.

3 Set the blink parameters.

• When key blink is selected

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Blink Rate

Length of blink cycle

1 to 100

 

 

 

 

2

Duty

Proportion of cycle for which key

0.00 to 100.00

 

 

inserted

 

 

 

 

 

222 Key Setting Operations Using Menus