Keys 4 Chapter
2 In the <DME Select> group, select the DME channel (DME1 to DME8) to be used.
The colors with which [DME1] to [DME8] are lit show the key assignment status.
Lit green: The DME currently being monitored
Lit amber: DME assigned to KEY
Off: Unassigned DME
In the
3 Press [Monitor Set].
This assigns the selected DME output to DME MON V and DME MON K.
Blink Function
With the blink function, you can obtain the following effects.
Key blink: The key is alternately inserted and deleted at regular intervals. You can set the period of blinking, and the proportion of each cycle for which the key is inserted.
Edge blink: The key fill and key edge fill signals are interchanged at regular intervals. You can set the period of blinking, and the proportion of each cycle for which the original state holds.
Using the blink function
For example, to make the required settings for key 1 on the
1 In the
The Transition menu appears.
2 In the <Blink> group, select [Key Blink] or [Edge Blink] to set it on.
3 Set the blink parameters.
• When key blink is selected
Knob | Parameter | Adjustment | Setting values |
|
|
|
|
1 | Blink Rate | Length of blink cycle | 1 to 100 |
|
|
|
|
2 | Duty | Proportion of cycle for which key | 0.00 to 100.00 |
|
| inserted |
|
|
|
|
|
222 Key Setting Operations Using Menus