Knob

Parameter

Adjustment

Setting values

 

 

 

 

2

Soft

Edge softness of pattern

0.00 to 100.00

 

 

 

 

You can carry out knob adjustment of the parameters Size and Soft in the Composite Adjust menu.

• When [Ext Key] is selected

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Clip

Reference level for key

–7.30 to +109.58

 

 

signal generation

 

 

 

 

 

2

Gain

Key sensitivity

–100.00 to +100.00

 

 

 

 

• When Mix is selected

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Mix Rate

Mix proportion

0.00 to 100.00

 

 

 

 

4 When you selected a pattern key, set the pattern modifiers as required.

The effect of the modifier parameters on the pattern is the same as for pattern modifiers with a mask setting (see page 270).

• When turning [Position] on and setting the pattern position

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Position H

Horizontal position

100.00 to +100.00 a)

2

Position V

Vertical position

100.00 to +100.00 a)

a) See page 51.

• When turning [Multi] on and replicating the pattern

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

H Multi

Number of repetitions of

1 to 63

 

 

pattern horizontally

 

 

 

 

 

2

V Multi

Number of repetitions of

1 to 63

 

 

pattern vertically

 

 

 

 

 

3

Invert Type

Replication layout

1 to 4 a)

a)See page 53.

Memory Frame 7 Chapter