Functions
a) When a value is smaller than 1, 1/Aspect or 1/Perspective (z) is adjusted to an integral value.
Each of the transformation operation modes has default values for three- dimensional parameters. If required, you can return the current value to the defaults by pressing the [CTR] button in the device control block twice in rapid succession. (For details, see
The following table shows the default parameter values for each transformation operation mode.
Operation mode | Default value |
|
|
Location XYZ | 0.00 |
|
|
Rotation, Spin | 0.00 |
|
|
Axis Location | 0.00 |
|
|
Location Size | 1.00 |
|
|
Aspect | 1.00 |
|
|
Perspective (x, y) | 0.00 |
Perspective (z) | 1.00 |
|
|
Skew | 0.00 |
|
|
Resetting of parameter values set in the source coordinate space
In some transformation operation modes, if you switch to the target coordinate space after setting up a
Once a conversion has taken place, the original source coordinate space parameters do not return to their original values when you switch back to the source coordinate space. They are reset to zeros.
Source/target conversion occurs in the following operation modes:
•Location XYZ
•Rotation
Transformation Operation Modes
The following operation modes are available for
76 Digital Multi Effects (DME)