Functions
Setup Relating to the Router Interface and Tally Interface
Carry out settings relating to the interface with the routing switcher, and settings relating to the tally interface.
You can make the following settings.
Router interface setup (Router)
•Matrix Size: Assign the switcher matrix of each switcher processor to
•External Box: To obtain the signal selection status of external devices with a parallel input, assign a matrix as an external selector in the
Tally interface setup (Tally)
Group tally settings (Group Tally)
•Tally Group: Select the group tally (Gp1 to 4 or Gp5 to 8) which can be used.
•
Wiring information input (Wiring)
Input the information which specifies the physical wiring between switcher and routing switcher or between two routing switchers.
Tally enable settings (Tally Enable)
Specify the destination to be the reference for tally generation, and make various settings.
•Tally Type: Specify the tally type. The tally types which can be specified are as follows:
When Group Tally is Gp1 to 4: R1, R2, R3, R4, G1, G2, G3, G4
When Group Tally is Gp5 to 8: R5, R6, R7, R8, G5, G6, G7, G8
•Destination: Specify the address and level.
•Tally Enable: Specify the timing at which a tally is enabled.
Enable: Always enabled.
Disable: Always disabled.
Tally Input No.: Follow the tally input status.
Copy (Tally Copy)
Copy the tally information pertaining to a particular source to a different source.
132 Setup