Wipes 5 Chapter

Setting the wipe pattern replication (Multi)

You can set pattern replication independently for the main pattern and sub pattern.

Use the following procedure.

1

In the M/E-1> Wipe menu, select HF5 ‘Main Modify.’

 

The Main Modify menu appears.

 

2

Press the [Multi] button, turning it on.

 

3

Set the following parameters.

 

 

 

 

 

 

 

Knob

Parameter

Adjustment

Setting values

 

 

 

 

 

 

1

H Multi

Number of repetitions of pattern

1 to 63

 

 

 

horizontally

 

 

 

 

 

 

 

2

V Multi

Number of repetitions of pattern

1 to 63

 

 

 

vertically

 

 

 

 

 

 

 

3

Shift

Replication layout

100.00 to +100.00 a)

a) See page 53.

4 To make more adjustments, press the [Multi Adjust] button.

The Multi Adjust menu appears.

5 Make the following settings, as required.

H Invert: When this is on, alternate tiles are inverted left-to-right.

V Invert: When this is on, alternate tiles are inverted top-to-bottom.

Non-Mask:When this is on, even if the positioner function is used to move the pattern position, the pattern is always present on the screen.

Position: By adjusting the following parameters, move the pattern position within the divisions determined in step 3.

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Position H

Horizontal position of pattern

200.00 to +200.00 a)

2

Position V

Vertical position of pattern

200.00 to +200.00 a)

a) See page 51.

Making a wipe pattern like a Venetian blind (Pairing)

Use the following procedure.

1 In the M/E-1 > Wipe menu, select HF5 ‘Main Modify.’ The Main Modify menu appears.

250 Basic Procedure for Wipe Settings