www.ti.com

MDIO Registers

4.13 MDIO User PHY Select Register 0 (USERPHYSEL0)

The MDIO user PHY select register 0 (USERPHYSEL0) is shown in Figure 27 and described in Table 26.

Figure 27. MDIO User PHY Select Register 0 (USERPHYSEL0)

31

 

 

 

 

 

16

 

 

Reserved

 

 

 

 

 

R-0

 

 

 

 

15

8

7

6

5

4

0

Reserved

 

LINKSEL

LINKINTENB

Reserved

 

PHYADRMON

R-0

 

R/W-0

R/W-0

R-0

 

R/W-0

LEGEND: R = Read only; R/W = Read/Write; -n= value after reset

Table 26. MDIO User PHY Select Register 0 (USERPHYSEL0) Field Descriptions

Bit

Field

Value

Description

31-8

Reserved

0

Reserved

7

LINKSEL

 

Link status determination select bit. Default value is 0 which implies that the link status is

 

 

 

determined by the MDIO state machine. This is the only option supported on this device.

6

LINKINTENB

 

Link change interrupt enable. Set to 1 to enable link change status interrupts for PHY address

 

 

 

specified in PHYADRMON. Link change interrupts are disabled if this bit is set to 0.

 

 

0

Link change interrupts are disabled

 

 

1

Link change status interrupts for PHY address specified in PHYADDRMON bits are enabled

5

Reserved

0

Reserved

4-0

PHYADRMON

 

PHY address whose link status is to be monitored

78

Ethernet Media Access Controller (EMAC)/Management Data Input/Output (MDIO)

SPRU975B –August 2006

Submit Documentation Feedback

Page 78
Image 78