www.ti.com
MDIO Registers
4.8MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)
The MDIO user command complete interrupt (unmasked) register (USERINTRAW) is shown in Figure 22 and described in Table 21.
Figure 22. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)
31 |
|
| 16 |
Reserved |
|
|
|
|
|
| |
15 | 2 | 1 | 0 |
Reserved |
| USERINTRAW | |
|
LEGEND: R = Read only; R/WC = Read/Write 1 to clear;
Table 21. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW) Field
Descriptions
Bit | Field | Value | Description |
| Reserved | 0 | Reserved |
USERINTRAW |
| MDIO User command complete event bits. When asserted, a bit indicates that the previously | |
|
|
| scheduled PHY read or write command using that particular USERACCESS register has |
|
|
| completed. Writing a 1 will clear the event and writing 0 has no effect. |
SPRU975B | Ethernet Media Access Controller (EMAC)/Management Data Input/Output (MDIO) | 73 |
Submit Documentation Feedback |
|
|