| Analog Programming Mode |
|
|
|
| ||
To activate APG voltage mode using an external resistor: |
| ||
1. | Turn the |
| |
| rotary Adjust/Enter control if the mode control is already at the VAP |
| |
| position. |
| |
| UAPr is displayed on the output voltage display. |
| |
2. | Turn the rotary Adjust/Enter control to select Rn1S (resistor source |
| |
| from |
| |
3. | Press the rotary Adjust/Enter control to commit the selected mode. |
| |
| LE U is displayed on the output voltage display. |
| |
4. | Select the input source level using the rotary Adjust/Enter control. |
| |
5. | Once the desired level has been selected, press the rotary Adjust/Enter |
| |
| control to commit the change. |
| |
| The display will return to the normal display. |
|
|
|
|
| |
Deactivating APG Voltage Mode |
| 4 | |
To deactivate the APG voltage mode: |
| ||
|
| ||
1. | Turn the |
| |
| rotary Adjust/Enter control if the mode control is already at the VAP |
| |
| position. |
| |
2. | UAPr is displayed on the output voltage display. |
| |
3. | Turn the rotary Adjust/Enter control to select nonE. |
| |
4. | Press the rotary Adjust/Enter control to commit the change. |
| |
| The display will return to the normal display. |
|