Configure Other Protection Mechanisms

Protection Mask (Enable Alarms)

The protection mask allows for the different alarms to be masked, completely disabling them. This means that the SCPI status and operations registers will not detect the alarms. You will have no way of knowing the current operation state of the alarm. The protection mask is a feature that is only accessible using the SCPI command noted below.

Command:

[:]SYSTem[<channel>]:PROTection[:MASK] {?<mask>}

Where

<mask> is the bit mask for disabling the alarms. See Table 5-19 for details.

Table 5-19Alarms Bit Mask

Bit

Bit Weight

Bit Name

Description

 

 

 

 

 

 

0

1

AC Fail

Not used. Always 1.

 

 

 

 

 

 

1

2

OTP

Over Temperature protection.

 

 

 

 

 

 

2

4

N/A

Not used.

 

 

 

 

 

 

3

8

Fan Stop

Fan on the main board.

 

 

 

 

 

 

4

16

N/A

Not used.

 

 

 

 

 

 

 

5

32

Interlock

Not used. Always 1.

 

 

 

 

 

 

6

64

OVP

Not used. Always 1.

5

 

 

 

 

7

128

OCP

Not used. Always 1.

8

256

Foldback

Foldback protection.

 

 

 

 

 

 

9

512

Shutdown

External Shutdown pin

 

 

 

 

 

 

10

1024

UVP

Under Voltage protection.

 

 

 

 

 

 

See “Alarms and Errors” on page 3–18.