Locking and Unlocking the Front Panel
Another benefit to the readback command is it allows the auto sequence program to be captured and stored on the client side for reloading when the program is to persist beyond power cycles.
Command:
[:]PROGram[<channel>]:READback? For Example:
:PROG:START
*CLS :VOLT 5.4 :CURR 0.25 *IDN? :PROG:STOP :PROG:READ?
Response:
*CLS :VOLT 5.4 :CURR 0.25 *IDN? :PROG:STOP
Reloading an Auto Sequence Program: | 5 | ||
| The following procedure will demonstrate how to store a command | ||
|
| ||
| beyond a power cycle of the unit. |
| |
|
|
| |
| Important: This functionality is only available through USB, |
| |
|
| ||
| ENET cards. |
| |
| To reload Auto Sequence program from file: |
| |
1. | Set the data rate of the device to be 1200 bps. |
| |
2. | Close the connection to the hyperterminal program and configure the |
| |
|
| connection data rate to be 1200 bps. |
|
3. | Execute the program recording command: |
|
:PROG:START