Local Operation

Quick Tip Remote operation uses these SCPI commands. See page 5–1.

Important: The control circuits have been designed to allow you to set the output voltage up to 105% over the model-rated maximum value. The power supply will operate within these extended ranges, but full performance to specification is not guaranteed.

The SCPI command (s) for these instructions are:

[[:]SOURce[<channel>]]:VOLTage[:LEVEl][:IMMediate]

[:AMPLitude]

Important: The maximum and minimum setting values of the output voltage are limited by the Over Voltage Protection and Under Voltage Protection settings.

To set the current set point (ISET):

1.Turn the 9-position mode control to the AMPS position or press the rotary Adjust/Enter control if the 9-position mode control is already at the AMPS position.

The voltage set point is blinking in the output voltage display. The output current will be displayed in the output current display.

2.Set the desired current value using the rotary Adjust/Enter control.

3.Press the rotary Adjust/Enter control to transition to Fine Adjust mode.

The set point blinks faster to indicate fine adjust tracking mode.

4.Set the desired current value using the rotary Adjust/Enter control.

5.Once the desired value has been set, press the rotary Adjust/Enter control to commit the setting.

Important: The control circuits have been designed so that output

current can be set up to 105% over the model-rated maximum values. The power supply will operate within these extended ranges, but full performance to specification is not guaranteed.

The SCPI command (s) for these instructions are:

[[:]SOURce[<channel>]]:CURRent[:LEVEl][:IMMediate]

[:AMPLitude]