Resetting the Power Supply

Resetting the Power Supply

 

The reset is used to clear the parameters to the factory default values.

 

Soft Reset

The soft reset is used to set the parameters (see Table 3-9) to the default

 

 

values, but it does not reset the calibration constants

 

 

To perform a soft reset:

 

 

1. Turn the power supply to Off then On.

 

 

When the unit is powering on, 8888 8888 is displayed on the output

 

 

voltage and current displays.

 

 

2. Press the key combination of both OUTPUT ENABLE Main button

 

 

and OUTPUT ENABLE Aux button and hold continuously for 3

 

 

 

 

seconds in order to execute.

3

 

If the flash fail alarm triggers, it is also possible to reset the power

 

supply.

3. Once a reset has been triggered, the output voltage display shows P5U CLr for 1 second.

The model number will be displayed for 1 second and then return to normal mode.

After executing a reset, the power supply’s settings are restored to the default settings but retain the calibration data. Table 3-9 lists the default settings.

Table 3-9Power Supply Default Settings

Parameter

Setting

 

 

Address

1

Data rate (Kbps)

9.6

Communication mode

RS-232

Vout setting

0 V

Iout setting

0 A

Output

Off

AUX Out

Off

Trigger

Off

Ext. On/Off Polarity

Negative

Auto start mode

Off

AUX Auto start mode

Off

OVP

Maximum

 

 

M370078-01

3-39

Page 83
Image 83
Xantrex Technology XG 850 manual Resetting the Power Supply, To perform a soft reset, 9Power Supply Default Settings