Analog Programming Mode

 

Resistive-Controlled Current APG Setup

 

To activate APG current mode using an external resistor source:

 

1.

Turn the 9-position mode control to the CAP position to press the

 

 

rotary Adjust/Enter control if the control knob is already at CAP

 

 

position.

 

 

CAPr is displayed on the output voltage display.

 

2.

Turn rotary Adjust/Enter control to select Rn1S (voltage source from

 

 

non-isolated connector).

 

3.

Press the rotary Adjust/Enter control to commit the selected mode.

 

 

LE C is displayed on the output voltage display.

 

4.

Once the desired level has been selected, press the rotary Adjust/Enter

 

 

control to commit the change.

 

 

The display will return to the normal display.

 

Deactivating APG Current Mode

 

 

To deactivate the APG current mode:

4

1.

Turn the 9-position mode control to the CAP position or press the

 

rotary Adjust/Enter control if the mode control is already at the CAP

 

 

 

 

position.

 

2.

CAPr is displayed on the output voltage display.

 

3.

Turn the rotary Adjust/Enter control to select nonE.

 

4.

Press the rotary Adjust/Enter control to commit the change.

 

 

The display will return to the normal display.

 