Enabling the Output

Shipped Configuration (Local Operation)

The power supply is configured for local operation at the factory. See Table 3-3 for a summary of this configuration. For more information on default settings, see Table 3-9 on page 3–39.

Table 3-3Shipped Configuration

Local Control Configuration

Additional References

 

 

 

 

 

Use the front panel controls to

See Chapter 3, “Local Operation” for front

 

adjust the output voltage and

panel operation. See Chapter 4, “Analog

 

current set point settings.

Programming (APG) and Isolated Analog

 

 

Programming (ISOL)” for analog

 

 

programming procedures.

 

The OVP set point is adjusted at

See “Using Over Voltage Protection

 

3

the front panel to 105% above the

(OVP)” on page 3–25 for the adjustment

maximum rated output voltage.

procedure.

 

 

 

 

Enabling the Output

Quick Tip Remote Operation uses these commands. See page 5–1.

Enabling the output on will also turn off the ALARM LED if the ALARM LED has been latched on due to an alarm triggering and automatically clearing. See “Alarms and Errors” on page 3–18.

To enable the output power:

Press the OUTPUT ENABLE Main button on the front panel or enter the SCPI command.

The OUTPUT ENABLE Main button will illuminate.

To disable the output power:

Press the OUTPUT ENABLE Main button when the OUTPUT ENABLE Main button is illuminated.

The output will be disabled and the LEDs will not be illuminated.

Important: The main output will not turn on if the shutdown function is activated. See “Using the External Shutdown Function” on page 3–30.

The SCPI command (s) for these instructions are:

[:]OUTPut[<channel>][:POWer][:STATe]