Introduction

Making Control Connections

CAUTION: Equipment damage

Before making connections from external circuits to the Analog Programming Connector, turn the front panel power switch to Off and wait until the front panel displays are not illuminated.

CAUTION: Equipment damage

Program/monitor signal and return are internally connected to the power supply negative output (-S). Do not attempt to bias these away from that potential.

To connect the output wires to the APG and DC output connector:

1.Insert a 3/32 inch slot-head screwdriver into the orange-colored box of the connector until the end of the spring is reached. See Figure 4-2.

2.Hold the connector open and insert the applicable output wire.

3.Remove the screwdriver.

4

Figure 4-2Inserting Screwdriver into Spring Terminal Block

Figure 4-3APG and DC Output Connector

M370078-01

4-7

Page 99
Image 99
Xantrex Technology XG 850 manual Making Control Connections, 2Inserting Screwdriver into Spring Terminal Block