Remote Operation

Set Remote Programming Interface

The remote source can be select using the following SCPI commands. These commands are equivalent to the procedure on “Voltage-Controlled Voltage APG Setup” on page 4–10 and “Voltage-Controlled Current APG Setup” on page 4–12.

Commands:

[:]SYSTem[<channel>]:REMote:SOURce[:VOLTage]

{?LOCalAVOLtageARESistive}

[:]SYSTem[<channel>]:REMote:SOURce:CURRent

{?LOCalAVOLtageARESistive}

Where:

LOCal indicates the value is controlled by the set point.

AVOLtage is used to set the output to be controlled by an analog voltage input.

ARESistive is used to set the output to be controlled by a resistor circuit.

IAVoltage is used to set the output to be controlled by the isolated analog voltage input.

IAResistive is used to set the output to be controlled by the isolated analog resistor circuit.

5-70

M370078-01

Page 196
Image 196
Xantrex Technology XG 850 manual Set Remote Programming Interface