Page 55
Image 55

Standard Operation

Standard Operation

The power supply can be controlled by two methods, either from the front panel or from any of the remote interfaces. Front panel control is referred to as local operation (default setting) while control via any of the remote interfaces is called remote operation. To set up the power supply for remote operation, see Chapter 5, “Remote Operation”. Once the remote connection has been established, the power supply can switch seamlessly between local operation and any digital interface (RS-232, RS-485, GPIB, USB and Ethernet).

 

Local lockout is a feature that allows the front panel to be locked so that

 

 

accidental button presses are ignored. This feature is often used to lock

 

 

 

 

out the front panel while a user is controlling the power supply from a

 

 

remote location.

3

 

The output of the power supply has two modes of operation: Constant

 

Voltage (CV) mode (see page 3–12) and Constant Current (CC) mode

 

 

 

 

(see page 3–12). Both of the operating modes are available regardless of

 

 

which control method (local or remote) is used.

 

Operating Modes

 

 

The output mode in which the power supply operates at any given time

 

 

depends on the following factors:

 

 

• Output voltage set point VSET

 

 

• Output current set point ISET

 

 

• Impedance of the attached load RL

 

 

The two output modes of operation are Constant Voltage (CV) mode (see

 

 

page 3–12) and Constant Current (CC) mode (see page 3–12).

 

Output enabled

When the output is turned on, both the voltage and current rise as quickly

 

 

as possible to try and reach the set points (VSET and ISET) that were

 

 

configured prior to enabling the output. Initially the unit will operate in

 

 

CV mode, which is the default mode. As the voltage and current rise to

 

 

meet the requirements of the load, the set point that is reached first (based

 

 

on the RL, either VSET or ISET) will determine which mode the power

 

 

supply will remain in. The operating mode is indicated by either the CC

 

 

mode LED or the CV mode LED, one of which will illuminate on the

 

 

front panel.

 

Output disabled

The mode of operation is not determined until the output is enabled. The

 

 

CV and CC mode LEDs will not indicate the mode while the output is

 

 

disabled.

 

M370078-01

3-11

Page 55
Image 55
Xantrex Technology XG 850 manual Standard Operation, Operating Modes