| OPERation Status Register |
|
Table | OPERation SHUTdown Status Register |
| |||
|
|
|
|
| |
Bit | Bit Weight | Bit Name | Description |
| |
|
|
|
|
|
|
0 | 1 |
| PROTection | Reflects the summary of the PROTection sub- |
|
|
|
|
| register. |
|
|
|
|
|
|
|
1 | 2 |
| INTerlock | The power supply is shut down by INTerlock signal. |
|
|
|
|
|
|
|
2 | 4 |
| Not Used | Not Used |
|
|
|
|
|
|
|
3 | 8 |
| External Shutdown | The power supply is shut down by External |
|
|
|
|
| Shutdown signal. |
|
|
|
|
|
|
|
Table | OPERation SHUTdown PROTection Status Register |
| |||
|
|
|
|
| |
Bit | Bit Weight | Bit Name | Description |
| |
|
|
|
|
|
|
0 | 1 |
| OVP | Over Voltage protection has tripped. |
|
|
|
|
|
|
|
1 | 2 |
| UVP | Under Voltage protection has tripped. |
|
|
|
|
|
|
|
2 | 4 |
| OCP | Over Current protection has tripped. |
|
|
|
|
|
|
|
3 | 8 |
| Not Used | Not Used |
|
|
|
|
|
|
|
4 | 16 |
| AC Off | AC failure protection has tripped. |
|
|
| ||||
|
|
|
|
|
|
5 | 32 |
| OTP | Over Temperature protection has tripped. |
|
|
|
|
|
| 5 |
6 | 64 |
| Not Used | Not Used | |
|
|
|
|
| |
7 | 128 |
| Foldback | Foldback protection has tripped. | |
|
| ||||
|
|
|
|
|
|
8 | 256 |
| Fan | Fan failure protection has tripped. |
|
|
|
|
|
|
|