OPERation Status Register

 

Table 5-12

OPERation SHUTdown Status Register

 

 

 

 

 

 

Bit

Bit Weight

Bit Name

Description

 

 

 

 

 

 

 

0

1

 

PROTection

Reflects the summary of the PROTection sub-

 

 

 

 

 

register.

 

 

 

 

 

 

 

1

2

 

INTerlock

The power supply is shut down by INTerlock signal.

 

 

 

 

 

 

 

2

4

 

Not Used

Not Used

 

 

 

 

 

 

 

3

8

 

External Shutdown

The power supply is shut down by External

 

 

 

 

 

Shutdown signal.

 

 

 

 

 

 

 

Table 5-13

OPERation SHUTdown PROTection Status Register

 

 

 

 

 

 

Bit

Bit Weight

Bit Name

Description

 

 

 

 

 

 

 

0

1

 

OVP

Over Voltage protection has tripped.

 

 

 

 

 

 

 

1

2

 

UVP

Under Voltage protection has tripped.

 

 

 

 

 

 

 

2

4

 

OCP

Over Current protection has tripped.

 

 

 

 

 

 

 

3

8

 

Not Used

Not Used

 

 

 

 

 

 

 

4

16

 

AC Off

AC failure protection has tripped.

 

 

 

 

 

 

 

 

 

5

32

 

OTP

Over Temperature protection has tripped.

 

 

 

 

 

 

5

6

64

 

Not Used

Not Used

 

 

 

 

 

7

128

 

Foldback

Foldback protection has tripped.

 

 

 

 

 

 

 

 

8

256

 

Fan

Fan failure protection has tripped.

 

 

 

 

 

 

 