| Table |
|
|
|
|
|
|
|
|
| Programming Mode | APG | ISOL | Digital |
|
|
|
|
|
| Voltage and Current Output Voltage Programming |
| ||
|
|
|
| |
| Votage and Current Output Resistive Programming |
| ||
|
|
|
| |
| Output Voltage and Current Monitor |
| ||
|
|
|
| |
| Voltage Programming Accuracy1 | ± 0.5% of rated output voltage, max. (0 to 4.0V / 4K Ohm range) | ±0.1% of rated output voltage | |
|
| ± 0.5% of rated output voltage, typical in other ranges |
| |
|
|
|
| |
| Current Programming Accuracy1 | ± 1.0% of rated output current, max. (0 to 4.0V / 4K Ohm range) | ±0.2% of rated output current | |
|
| ± 1.0% of rated output current, typical in other ranges |
| |
|
|
|
|
|
| Voltage Readback Accuracy | ± 1% of rated output voltage |
| ±0.1% of rated output voltage |
|
|
|
|
|
| Current Readback Accuracy | ± 1% of rated output current |
| ±0.2% of rated output current |
|
|
|
|
|
| Isolation (Prog and Readback Lines) | With respect to chassis potential: | With respect to: |
|
|
| 500 V | chassis potential: 500 V. |
|
|
|
| negative or positive main output: 1500 V. |
|
|
|
|
|
|
| Parallel Operation | Up to 4 units in master/slave mode |
|
|
|
|
|
|
|
| Series Operation | Up to 2 units (with external |
|
|
|
| diodes) |
|
|
|
|
|
|
|
| Constant Voltage (CV)/Constant Current (CC) Indicator | CV: TTL High |
|
|
|
| CC: TTL Low |
|
|
|
|
|
|
|
| Shutdown Control2 |
| Logic low 0.0 - 1.4V |
|
|
|
| Logic high 2.0 - 15V |
|
|
|
| Dry contact compatible |
|
|
|
|
|
|
| OUTPUT ENABLE Auxiliary Control |
| TTL level or dry contact compatible |
|
|
|
|
|
|
| Power Supply Status Signal |
| TTL high: OK |
|
|
|
| TTL low: fail |
|
|
|
|
|
|
| Interlock Enable/Disable |
| Dry contact. Open/Short: On or Off, |
|
| programmable |
| ||
|
|
|
| |
|
|
|
|
|
1.Typical APG or isolated APG accuracy can be improved to max accuracy by user calibration at the specific range selected. 2.The shutdown input has user selectable negative logic operation via front panel or remote digital input/output.
Specifications