Analog Programming (APG) and Isolated Analog Programming (ISOL)
4-4 M370078-01
Auxiliary Outputs
The auxiliary outputs are an additional isolated source. The auxiliary
output has two outputs: +5 V output on J3.9 and a +15 V output on J3.11.
The auxiliary output operates independently of the main output. It is
enabled or disabled from the front panel by pressing the OUTPUT
ENABLE Aux button. When the Aux output is enabled, the OUTPUT
ENABLE Aux button is illuminated. Like the main output of the power
supply, the Aux also has the ability to Autostart at power up. See “Output
Auto Start Mode (Auto Restart)” on page 3–16 and “Auxiliary Auto Start
Mode” on page 3–17 for details on controlling this feature.
Table 4-2 provides a summary of the options available for programming
output voltage and current set point using an analog source.
Table 4-2
Remote Programming Options
Control of… Programming Scale1
1.The resolution can be adjusted in increments of 0.1 volts.
For more info…
Output voltage 2–10 V Voltage source (adjustable) See page 4–10.
Current set point 2–10 V Voltage source (adjustable) See page 4–12.
Output voltage 2–10 kΩ Resistive source (adjustable) See page 4–15.
Current set point 2–10 kΩ Resistive source (adjustable) See page 4–17.