Remote Operation
Figure 5-18 summarizes the Standard Event Status Register.
Standard Event
Status Register
(SESR)
Operation Complete 0
Not Used 1
Query Error 2 Device Dependent Error 3
...
Execution Error 4
Command Error 5
Not Used 6
Power On 7
SESR
Summary
Bit
+
Status Byte
Register
Not Used 0
Not Used 1
Error/Event Queue Status Flag 2
QUEStionable Status Summary Bit 3
Not Used 4
5
6
OPERation Status Summary Bit 7
MSS
Summary
Bit
+
Figure | Summary of Standard Event Status Register | ||||||
Table | Standard Event Status Register |
|
| ||||
Bit |
| Bit Weight |
| Bit Name |
| Description | |
|
|
| |||||
|
|
|
|
|
|
|
|
0 |
| 1 |
|
| Operation Complete |
| Set if *OPC command has been received and all |
|
|
|
|
| (OPC) |
| pending operations have been completed. |
1 |
| 2 |
|
| Request Control (RQC) |
| Not implemented. Always set to 0. |
|
|
|
|
|
|
|
|
2 |
| 4 |
|
| Query Error (QYE) |
| Not implemented. |
|
|
|
|
|
|
|
|
3 |
| 8 |
|
| Device Dependent Error |
| Set if there is a |
|
|
|
|
| (DDE) |
| See |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| for a list possible error codes and descriptions. |
|
|
|
|
|
|
|
|
4 |
| 16 |
|
| Execution Error (EXE) |
| Set if a program data element, following a header, |
|
|
|
|
|
|
| was evaluated by the power supply as outside of its |
|
|
|
|
|
|
| legal input range, or is otherwise inconsistent with |
|
|
|
|
|
|
| the power supply’s capabilities. Suggests that a |
|
|
|
|
|
|
| valid program message could not be properly |
|
|
|
|
|
|
| executed due to some power supply condition. |
|
|
|
|
|
|
| See “Execution Error List” on page |
|
|
|
|
|
|
| possible error codes and descriptions. |
|
|
|
|
|
|
|
|