Remote Operation

Figure 5-18 summarizes the Standard Event Status Register.

Standard Event

Status Register

(SESR)

Operation Complete 0

Not Used 1

Query Error 2 Device Dependent Error 3

...

Execution Error 4

Command Error 5

Not Used 6

Power On 7

SESR

Summary

Bit

+

Status Byte

Register

Not Used 0

Not Used 1

Error/Event Queue Status Flag 2

QUEStionable Status Summary Bit 3

Not Used 4

5

6

OPERation Status Summary Bit 7

MSS

Summary

Bit

+

Figure 5-18

Summary of Standard Event Status Register

Table 5-10

Standard Event Status Register

 

 

Bit

 

Bit Weight

 

Bit Name

 

Description

 

 

 

 

 

 

 

 

 

 

 

0

 

1

 

 

Operation Complete

 

Set if *OPC command has been received and all

 

 

 

 

 

(OPC)

 

pending operations have been completed.

1

 

2

 

 

Request Control (RQC)

 

Not implemented. Always set to 0.

 

 

 

 

 

 

 

 

2

 

4

 

 

Query Error (QYE)

 

Not implemented.

 

 

 

 

 

 

 

 

3

 

8

 

 

Device Dependent Error

 

Set if there is a device-specific error.

 

 

 

 

 

(DDE)

 

See “Device-Specific Error List” on page B–5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for a list possible error codes and descriptions.

 

 

 

 

 

 

 

 

4

 

16

 

 

Execution Error (EXE)

 

Set if a program data element, following a header,

 

 

 

 

 

 

 

was evaluated by the power supply as outside of its

 

 

 

 

 

 

 

legal input range, or is otherwise inconsistent with

 

 

 

 

 

 

 

the power supply’s capabilities. Suggests that a

 

 

 

 

 

 

 

valid program message could not be properly

 

 

 

 

 

 

 

executed due to some power supply condition.

 

 

 

 

 

 

 

See “Execution Error List” on page B–4 for a list of

 

 

 

 

 

 

 

possible error codes and descriptions.

 

 

 

 

 

 

 

 