List of editing command
141
AW2400 Owner’s Manual
Track operations and editing
15

Exchanges data between the specified tracks.

*1. The items that you can select in D To TR (copy-destination track)
will depend on the A From TR (copy-source track) setting.
If A From TR is a single audio track 1–24, you can select only a sin-
gle audio track 1–24.
If A From TR is ST or 1&2–23&24 (a pair of adjacent audio tracks),
you can select only 1&2–23&24 (a pair of adjacent audio tracks).

Adjusts the length of the specified region of an audio

track, without changing the pitch.

If you set Ratio = 50%

If you set Ratio = 200%

Parameter Range Explanation
AFrom TR
1–24 A single audio track
1&2–23&24 A pair of adjacent odd-numbered/
even-numbered audio tracks
ST The stereo track
BFrom V.TR 1–8 Exchange-source virtual track
number
CName
Up to eight
alphanumeric
characters
Exchange-source virtual track
name (display only)
DTo TR *1
1–24 A single audio track
1&2–23&24 A pair of adjacent odd-numbered/
even-numbered audio tracks
ETo V.TR 1–8 Exchange-destination virtual track
number
FName
Up to eight
alphanumeric
characters
Exchange-destination virtual track
name (display only)
EXCHANGE
C

AB

DEF

EXCHANGE
From
Track
To
Track
From
Track
To
Track
1 2 3 4 5 6
A B C D E F
1 2 3 4 5 6
A B C D E F
Parameter list
• The track names will not be exchanged.
NOTE
Parameter Range Explanation
AFrom TR
1–24 A single audio track
1&2–23&24 A pair of adjacent odd-numbered/
even-numbered audio tracks
ST The stereo track
BFrom V.TR 1–8 Virtual track number
CFrom Start Specify a point Beginning of the edited region
DFrom End Specify a point End of the edited region
ETO END Specify a point
Specify the length to which the
selected region will be com-
pressed or expanded
FTo Ratio 50–200%
Specify the percentage by which
the selected region will be com-
pressed or expanded
TIME COMP (Time Compression/Expansion)
EF

AC D

B
TIME
COMP/EXP
From End
1 2 3 4 A B C D
12 3 4 A B C D
From Start
To END
TIME
COMP/EXP
From End
1 2 3 4 A B C D
1C D
From Start
To END
2 3 4
Parameter list
•TO END and To Ratio are linked, so that editing one field will
cause the other field to change.
•You cannot set TO END or To Ratio to a value that would cause
the ratio to exceed 50–200 percent.
•From Start value and From End value must be at least 45 msec
apart. These cannot be set to a shorter interval.
NOTE