Finding a location while viewing the waveform
95
AW2400 Owner’s Manual
Transport/Locate Operation
9

The AW2400 lets you find a location while viewing the waveform of the sound recorded on a

track.

1Locate to the vicinity of the point you want
to find.
2Call the TRACK screen Track View page by
either pressing the Work Navigate section
[TRACK] key as many times as necessary,
or by pressing the [F1] key after pressing
the [TRACK] key.
3Move the cursor to the TRACK field, and
use the [DATA/JOG] dial or [INC]/[DEC] keys
to select the number of the track corre-
sponding to waveform you want to view.
4Move the cursor to the WAVE button and
press the [ENTER] key.
The WAVE DISPLAY popup window will appear.
This popup window displays the waveform of the
audio data recorded in the track selected in step 3 (1–
24 or ST-L/R).
1TRACK
Indicates the currently selected track number. You can
also move the cursor to this field and use the [DATA/
JOG] dial or [INC]/[DEC] keys to switch tracks.
BCounter
Displays the location of the vertical line (pointer) indi-
cating the current location in the WAVE DISPLAY
popup window. You can move the cursor to this field
and use the [DATA/JOG] dial or [INC]/[DEC] keys to
move the current location forward or backward.
CSCALE
By moving the cursor to this area and using the
[DATA/JOG] dial or [INC]/[DEC] keys you can
expand or shrink the waveform display along the time
axis. The value of this field indicates the length of time
displayed in the WAVE DISPLAY popup window.
If you select 1SEC, the distance from the left to right
edge of the screen will correspond to one second.
Selecting SAMPLE will produce the highest magnifi-
cation, and each horizontal pixel will correspond to
one sample.
DAMP
By moving the cursor to this area and using the
[DATA/JOG] dial or [INC]/[DEC] keys you can
expand or shrink the waveform display along the
amplitude axis. The value of this field indicates the
level range of the waveform displayed in the WAVE
DISPLAY popup window. If you select 0 dB, the top
and bottom edges of the screen will correspond to the
maximum level.
ELISTEN button
If you move the cursor to this button and press the
[ENTER] key the waveform in the display area of the
WAVE DISPLAY popup window will be played once.
During playback the vertical line (pointer) that indi-
cates the current location will move, and the counter
value will change accordingly.
Normal transport operation is disabled while using the
LISTEN button.
FEXIT button
Move the cursor to this button and press the [ENTER]
key to exit the WAVE DISPLAY popup window and
return to the previous Track View page.
Finding a location while viewing the waveform
TRACK field
WAVE button
B
D
E
F
C
A
• The WAVE DISPLAY popup window cannot be displayed
while the recorder is running.
•You can use the Mixer section [SEL] or [STEREO SEL] keys
to switch the track being viewed even after displaying the
WAVE DISPLAY popup window.
HINT