Level Meter Types

GPEAK HOLD button

This button switches the level meter peak hold function on/off. When this button is on, an indicator will show the signal peaks.

HINT

The Input/RTN page and Track page PRE EQ/PRE FADER/POST FADER button settings are linked, while the Master page settings are independent.

The PEAK HOLD button setting affects all METER pages.

Pressing the [F1] key while holding the Display section [SHIFT] key has the same effect as the PEAK HOLD button.

METER screen Master page ([F3] key)

Displays the output and fader levels for BUS1 L/R, BUS2 L/R, AUX bus 1–4, effect bus 1–4, and the stereo bus.

A B C

10

Meters

D

E F G H

The following items are displayed:

1BUS1 L/R, BUS2 L/R output levels

B AUX bus 1–4 output levels C Effect bus 1–4 output levels D Stereo bus output level

The level meters display the output levels for the corre- sponding channels, while the numbers below the level meters show the fader levels in dB.

EPRE EQ button

Pre-EQ levels (levels prior to the EQ stage) are displayed when this button is on.

FPRE FADER button

Pre-fader levels (levels prior to the faders) are displayed when this button is on.

GPOST FADER button

Post-fader levels (levels after the faders) are displayed when this button is on.

HPEAK HOLD button

This button switches the level meter peak hold function on/off.

HINT

These PRE EQ/PRE FADER/POST FADER settings are indepen- dent from those on other pages.

The PEAK HOLD button setting affects all METER pages.

Pressing the [F1] key while holding the Display section [SHIFT] key has the same effect as the PEAK HOLD button.

METER screen Output page ([F4] key)

Displays the output and fader levels for a digital I/O card installed in the card slot, the [OMNI OUT] 1–4 outputs, and the [DIGITAL STEREO OUT] outputs.

A

B C D

The following items are displayed:

1Output levels for the card installed in the

slot

B[OMNI OUT] 1–4 output levels

C[DIGITAL STEREO OUT] output levels

The level meters display the output levels for the corre- sponding channels, while the numbers below the level meters show the fader levels in dB.

DPEAK HOLD button

This button switches the level meter peak hold function on/off.

HINT

The PEAK HOLD button setting affects all METER pages.

Pressing the [F1] key while holding the Display section [SHIFT] key has the same effect as the PEAK HOLD button.

98

AW2400 Owner’s Manual

Page 98
Image 98
Yamaha AW2400 owner manual Meter screen Output page F4 key, Peak Hold button, Level Meter Types