EQ/Dynamics Processor Library Operation

3 Press the Display section [F2] key, or press the [DYN] key as many times as necessary until the Gate Lib. page appears.

B C F

A

D

E

The Gate Lib. page includes the following items.

1Current Type

The currently selected gate type for the currently selected channel.

BCurrent Gate Response

A graphic representation of the current gate response for the currently selected channel. The horizontal axis represents input level, and the vertical axis represents output level.

CMeter

Displays the signal level after the gate, and the amount of gain reduction.

DGate Curve

A graphic representation of the gate curve of the cur- rently selected gate setting in the library list.

EList

A list of all the settings stored in the library. The row highlighted by a dotted frame is the setting currently selected for operation. An icon indicates read-only library settings.

FButtons

These buttons execute the RENAME, RECALL, STORE, and CLEAR functions. Detailed description of their operation begins on page 156.

Recalling Compressor Library Settings

From this library you can recall compressor settings to the currently selected channel. Of library numbers 001–128, numbers 001–036 are read-only, and 037–128 can be used to store your own settings.

Compressor library operations are performed via the DYNAMICS screen Comp Lib. page.

1 Use the Layer section, [INPUT SEL], [SEL], and [STEREO SEL] keys to select the target channel.

2 Press the Selected Channel section [DYN] key so that its indicator lights, then press Selected Channel knob 1, 2, 3, or 4.

The DYNAMICS screen will appear.

3 Press the Display section [F4] key, or press the [DYN] key as many times as necessary until the Comp Lib. page appears.

B C F

A

D

E

The Comp Lib. page includes the following items.

1Current Type

The currently selected compressor type for the cur- rently selected channel.

BCurrent Compression Response

A graphic representation of the current compression response for the currently selected channel. The hori- zontal axis represents input level, and the vertical axis represents output level.

CMeter

Displays the signal level after the compressor, and the amount of gain reduction.

DCompression Curve

A graphic representation of the compression curve of the currently selected compressor setting in the library list.

EList

A list of all the settings stored in the library. The row highlighted by a dotted frame is the setting currently selected for operation. An icon indicates read-only library settings.