Applying Compression to an Input Signal
61
AW2400 Owner’s Manual
Track recording
6

The AW2400 provides dynamics processing capability on all input and track channels: compres-

sion on the track channels, and both compression and gating on the input channels. The dynam-

ics processor parameters are adjusted manually via the Selected Channel section in the same

way as the EQ parameters. A range of dynamics presets for a variety of instruments is also pro-

vided in the dynamics library.

In this section we’ll see how to recall dynamics processor preset from the library and apply com-

pression to the channel 1–8 signals.

1Press the Layer section [IN 1-8] key so that
its indicator lights, the press the [SEL] key
for the channel to which compression is to
be applied.
2Press the Selected Channel section [DYN]
key so that its indicator lights.
The DYNAMICS screen will appear.
3Press the Display section [F3] key, or press
the [DYN] key as many times as necessary
until the Comp Edit page appears.
The compressor settings are available via this page.
4Move the cursor to the COMP ON/OFF but-
ton and press the [ENTER] key to turn the
compressor on.
This activates the compressor for the corresponding
input channel.
5Press the Display section [F4] key.
The DYNAMICS screen Comp Lib. page will appear.
Compressor library presets can be recalled via this
page. The currently selected compressor type and its
graphic response curve are shown at the top of the dis-
play.
6Use the [DATA/JOG] dial or [INC]/[DEC]
keys to select the library setting to be
recalled.
The setting highlighted by a dotted frame is currently
selected for recall.
Each setting has a name that indicates the instrument
or application it is intended to be used for. The com-
pressor types and response curves are displayed to the
left of the list.
Applying Compression to an Input Signal
• The [INPUT SEL] 1–8 keys can also be used to select an
input channel for compression.
HINT
• If the AUTO DISPLAY function is set to OFF, the DYNAMICS
screen will not appear automatically when the [DYN] key is
pressed. In this case press one of the Selected Channel
knobs (1–4) after pressing the [DYN] key so that its indicator
lights. For details about the AUTO DISPLAY function refer to
“AW2400 Preferences” on page 210.
NOTE
COMP ON/OFF button
•Pages can also be switched by repeatedly pressing a
Selected Channel knob.
HINT
• If necessary the individual compressor parameters can be
adjusted via this page. Refer to “Using the Compressors” on
page 152 for details.
HINT
List RECALL button