Adjusting the position of a locate point or marker
91
AW2400 Owner’s Manual
Transport/Locate Operation
9
Here’s how you can adjust the position of a previously-registered locate point or marker. These
operations are performed via the EDIT screen Mark Adj. page.
To call this page press the Work Navigate section [EDIT]
key as many times as necessary, or press the [F3] key after
pressing the [EDIT] key.
1Locator Position field
Shows the various locate points (Quick Locator points not
included).
BQuick Locator/Marker field
Shows the Quick Locator or Marker points.
CLOCATOR button
DMARKER button
These buttons determine whether the Quick Locator or
Marker points appear in the Quick Locator/Marker field.
EDELETE button (Marker display only)
Deletes the currently selected marker.
1Call the EDIT screen Mark Adj. page by
either pressing the Work Navigate section
[EDIT] key as many times as necessary, or
by pressing the [F3] key after pressing the
[EDIT] key.
2The Locator Position field is used to edit
the various locate points (not including the
Quick Locator points).
The positions for each locator are displayed in the
Locator Position field.
1Locate points
Shows the type of locate point and its abbreviation.
BPosition
Shows the position of each locate point in time code or
the current counter display format.
CMeasure/beat
Shows the position of each locate point as measures/
beats. This value is calculated based on the tempo and
time signature of the tempo map ( p. 175).
The format in which the position is displayed will
depend on the locate point. The following table shows
the display format for each locate point.
Adjusting the position of a locate point or marker
B
D
E
C
A
Locate point Position Measure/Beat
REL.ZERO Time code --
START Time code Measure/beat
END Time code Measure/beat
IN Counter display format Measure/beat
OUT Counter display format Measure/beat
ACounter display format Measure/beat
BCounter display format Measure/beat

Adjusting the position of

a locate point

BC
A
If a locate point has not been registered “--” will appear in the
numerical field.
HINT