Dynamics Parameters

Gate and Ducking

dB

+20

+10

0Threshold = –10dB

Level

–10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

–40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–30

 

 

 

 

 

 

 

Range = –30dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range = –70dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–70

–60

–50

–40

–30

–20

–10

0

+10

+20

 

Input Level

 

 

dB

 

 

 

 

 

 

 

 

 

 

+20

 

 

 

 

 

 

 

 

 

 

 

+10

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

Level

–10

Threshold = –20dB

 

 

 

 

 

 

 

 

 

 

 

–20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

–30

 

 

 

 

 

 

 

 

 

 

–40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–50

 

 

 

 

 

 

 

 

 

 

 

–60

 

 

 

 

 

 

Range = –30dB

 

–70

 

 

 

 

 

 

 

 

 

dB

 

 

 

 

 

 

 

 

 

 

 

 

 

–70

–60

–50

–40

–30

–20

–10

0

+10

+20

Input Level

A gate, or noise gate is an audio switch used to mute sig- nals below a set threshold level. It can be used to suppress background noise and hiss from valve (tube) amps, effects pedals, and microphones.

Ducking is used to automatically reduce the levels of one signal when the level of a source signal exceeds a speci- fied threshold. It is used for voice-over applications where, for example, level of background music is auto- matically reduced, allowing an announcer to be heard clearly.

Gate (GAT) and Ducking (DUK) parameters:

Parameter

Value

Threshold (dB)

-54 to 0 (541 points)

 

 

Range (dB)

-70 to 0 (701 points)

 

 

Attack (ms)

0 to 120 (121 points)

 

 

Hold (ms)

0.02 ms to 2.14 sec (216 points)

 

 

Decay (ms)

6 ms to 46.1 sec (160 points)

 

 

Threshold — sets the level at which the gate closes, cut- ting off the signal. Signals above the threshold level pass through unaffected. Signals at or below the threshold cause the gate to close.

For ducking, trigger signal levels at and above the thresh- old level activate ducking, and the signal level is reduced to a level set by the Range parameter.

The trigger signal is determined using the KEYIN

SOURCE parameter.

Appendix

Range — controls the level to which the gate closes. It can be used to reduce the signal level rather than cut it completely. At a setting of -70 dB, the gate closes com- pletely when the input signal falls below the threshold. At a setting of -30 dB, the gate only closes so far allowing an attenuated signal through. At a setting of 0 dB, the gate has no effect. When signals are gated abruptly, the sudden cutoff can sound odd.

For ducking, a setting of -70 dB causes the signal to be virtually cutoff. At a setting of -30 dB the signal is ducked by 30 dB. At a setting of 0 dB, the duck has no effect.

Attack — determines how fast the gate opens when the signal exceeds the threshold level. Slow attack times can be used to remove the initial transient edge of percussive sounds. Too slow an attack time makes some signals sound backwards.

For ducking, this controls how soon the signal is ducked once the duck has been triggered. With a fast attack time, the signal is ducked almost immediately. With a slow attack time, ducking fades the signal. Too fast an attack time may sound abrupt.

Hold — sets how long the gate stays open or the ducking remains active once the trigger signal has fallen below the threshold level.

Decay — controls how fast the gate closes once the hold time has expired. A longer decay time produces a more natural gating effect, allowing the natural decay of an instrument to pass through.

For ducking, this determines how soon the ducker returns to its normal gain after the hold time has expired.

242

AW2400 Owner’s Manual

Page 242
Image 242
Yamaha AW2400 owner manual 242, Gate GAT and Ducking DUK parameters