Chapter 29 IDP

Figure 323 Anti-X > IDP > Profile

The following table describes the fields in this screen.

Table 130 Anti-X > IDP > Profile

LABEL

DESCRIPTION

Name

This is the name of the profile you created.

 

 

Base Profile

This is the base profile from which the profile was created.

 

 

(Icons)

Click the Add icon in the column header to create a new profile. A pop-up screen

 

displays requiring you to choose a base profile from which to create the new profile.

 

Click an Edit icon to edit an existing profile.

 

Click a Remove icon to delete an existing profile.

 

 

29.7 Creating New Profiles

You may want to create a new profile if not all signatures in a base profile are applicable to your network. In this case you should disable non-applicable signatures so as to improve ZyWALL IDP processing efficiency.

You may also find that certain signatures are triggering too many false positives or false negatives. A false positive is when valid traffic is flagged as an attack. A false negative is when invalid traffic is wrongly allowed to pass through the ZyWALL. As each network is different, false positives and false negatives are common on initial IDP deployment.

You could create a new ‘monitor profile’ that creates logs but all actions are disabled. Observe the logs over time and try to eliminate the causes of the false alarms. When you’re satisfied that they have been reduced to an acceptable level, you could then create an ‘inline profile’ whereby you configure appropriate actions to be taken when a packet matches a signature.

29.7.1 Procedure To Create a New Profile

To create a new profile:

1Click the Add icon in the Anti-X > IDP > Profile screen to display a pop-up screen allowing you to choose a base profile.

2Select a base profile (see Table 129 on page 422) and then click OK to go to the profile details screen.

 

423