Appendix B Log Descriptions

 

Table 250 Device HA Logs (continued)

 

LOG MESSAGE

DESCRIPTION

 

 

Master configuration

The System Startup configuration file synchronized from the Master is

 

 

is the same with

the same with the one in the Backup, so the configuration does not

 

 

Backup. Skip updating

have to be updated.

 

 

it.

 

 

 

%s file not existed,

There is no file to be synchronized from the Master when syncing a

 

 

Skip syncing it for %s

object (AV/AS/IDP/Certificate/System Configuration), But in fact, there

 

 

 

should be something in the Master for the device to synchronize with,

 

 

 

1st %s: The syncing object, 2ed %s: The feature name for the syncing

 

 

 

object.

 

 

 

 

 

 

Master firmware

Synchronizing stopped because the firmware version file was not

 

 

version can not be

found in the Master. A Backup device only synchronizes from the

 

 

recognized. Stop

Master if the firmware versions are the same between the Master and

 

 

syncing from Master.

the Backup.

 

 

 

 

 

Device HA Sync has

The synchronization password was incorrect when attempting to

 

 

failed when syncing %s

synchronize a certain object (AV/AS/IDP/Certificate/System

 

 

for %s due to bad

Configuration).

 

 

\"Sync Password\".

1st %s: The object to be synchronized, 2ed %s: The feature name for

 

 

 

the object to be synchronized.

 

 

Device HA Sync has

The Sync From IP address or Sync Port may be incorrect when

 

 

failed when syncing %s

synchronizing a certain object (AV/AS/IDP/Certificate/System

 

 

for %s due to bad

Configuration).

 

 

\"Sync From\" or

 

 

 

\"Sync Port\".

 

 

 

Device HA Sync has

Synchronization failed when synchronizing a certain object (AV/AS/

 

 

failed when syncing %s

IDP/Certificate/System Configuration) due to an unknown reason, 1st

 

 

for %s.

%s: The object to be synchronized, 2ed %s: The feature name for the

 

 

 

object to be synchronized.

 

 

Sync Failed: Cannot

Synchronization failed because the Backup could not connect to the

 

 

connect to Master when

Master. The object to be synchronized, 2ed %s: The feature name for

 

 

syncing %s for %s.

the object to be synchronized.

 

 

Backup firmware

The firmware version on the Backup cannot be resolved to check if it is

 

 

version can not be

the same as on the Master. A Backup device only synchronizes from

 

 

recognized. Stop

the Master if the Master and the Backup have the same firmware

 

 

syncing from Master.

versions.

 

 

 

 

 

Sync failed: Remote

The firmware version on the Master cannot be resolved to check if it is

 

 

Firmware Version

the same as on the Master. A Backup device only synchronizes from

 

 

Unknown

the Master if the Master and the Backup have the same firmware

 

 

 

versions.

 

 

Master firmware

The Backup and Master have different firmware versions. A Backup

 

 

version should be the

device only synchronizes from the Master if the Master and the Backup

 

 

same with Backup.

have the same firmware versions.

 

 

Update %s for %s has

Updating a certain object failed when updating (AS/AV/IDP/Certificate/

 

 

failed.

System Configuration). 1st %s: The object to be synchronized, 2ed

 

 

 

%s: The feature name for the object to be synchronized.

 

 

Update %s for %s has

Updating a certain object failed when updating (AS/AV/IDP/Certificate/

 

 

failed: %s.

System Configuration) due to some reason. 1st %s: The object to be

 

 

 

synchronized, 2ed %s: The feature name for the object to be

 

 

 

synchronized.

 

 

 

 

 

 

Device HA has skipped

A certain service has no license or the license is expired, so it was not

 

 

syncing %s since %s is

synchronized from the Master. 1st %s: The object to be synchronized,

 

 

%s.

2ed %s: The feature name for the object to be synchronized, 3rd %s:

 

 

 

unlicensed or license expired.

 

 

691