| Appendix B Log Descriptions | |
| Table 250 Device HA Logs (continued) | ||
| LOG MESSAGE | DESCRIPTION |
|
| Master configuration | The System Startup configuration file synchronized from the Master is |
|
| is the same with | the same with the one in the Backup, so the configuration does not |
|
| Backup. Skip updating | have to be updated. |
|
| it. |
|
|
| %s file not existed, | There is no file to be synchronized from the Master when syncing a |
|
| Skip syncing it for %s | object (AV/AS/IDP/Certificate/System Configuration), But in fact, there |
|
|
| should be something in the Master for the device to synchronize with, |
|
|
| 1st %s: The syncing object, 2ed %s: The feature name for the syncing |
|
|
| object. |
|
|
|
|
|
| Master firmware | Synchronizing stopped because the firmware version file was not |
|
| version can not be | found in the Master. A Backup device only synchronizes from the |
|
| recognized. Stop | Master if the firmware versions are the same between the Master and |
|
| syncing from Master. | the Backup. |
|
|
|
| |
| Device HA Sync has | The synchronization password was incorrect when attempting to |
|
| failed when syncing %s | synchronize a certain object (AV/AS/IDP/Certificate/System |
|
| for %s due to bad | Configuration). |
|
| \"Sync Password\". | 1st %s: The object to be synchronized, 2ed %s: The feature name for |
|
|
| the object to be synchronized. |
|
| Device HA Sync has | The Sync From IP address or Sync Port may be incorrect when |
|
| failed when syncing %s | synchronizing a certain object (AV/AS/IDP/Certificate/System |
|
| for %s due to bad | Configuration). |
|
| \"Sync From\" or |
|
|
| \"Sync Port\". |
|
|
| Device HA Sync has | Synchronization failed when synchronizing a certain object (AV/AS/ |
|
| failed when syncing %s | IDP/Certificate/System Configuration) due to an unknown reason, 1st |
|
| for %s. | %s: The object to be synchronized, 2ed %s: The feature name for the |
|
|
| object to be synchronized. |
|
| Sync Failed: Cannot | Synchronization failed because the Backup could not connect to the |
|
| connect to Master when | Master. The object to be synchronized, 2ed %s: The feature name for |
|
| syncing %s for %s. | the object to be synchronized. |
|
| Backup firmware | The firmware version on the Backup cannot be resolved to check if it is |
|
| version can not be | the same as on the Master. A Backup device only synchronizes from |
|
| recognized. Stop | the Master if the Master and the Backup have the same firmware |
|
| syncing from Master. | versions. |
|
|
|
| |
| Sync failed: Remote | The firmware version on the Master cannot be resolved to check if it is |
|
| Firmware Version | the same as on the Master. A Backup device only synchronizes from |
|
| Unknown | the Master if the Master and the Backup have the same firmware |
|
|
| versions. |
|
| Master firmware | The Backup and Master have different firmware versions. A Backup |
|
| version should be the | device only synchronizes from the Master if the Master and the Backup |
|
| same with Backup. | have the same firmware versions. |
|
| Update %s for %s has | Updating a certain object failed when updating (AS/AV/IDP/Certificate/ |
|
| failed. | System Configuration). 1st %s: The object to be synchronized, 2ed |
|
|
| %s: The feature name for the object to be synchronized. |
|
| Update %s for %s has | Updating a certain object failed when updating (AS/AV/IDP/Certificate/ |
|
| failed: %s. | System Configuration) due to some reason. 1st %s: The object to be |
|
|
| synchronized, 2ed %s: The feature name for the object to be |
|
|
| synchronized. |
|
|
|
|
|
| Device HA has skipped | A certain service has no license or the license is expired, so it was not |
|
| syncing %s since %s is | synchronized from the Master. 1st %s: The object to be synchronized, |
|
| %s. | 2ed %s: The feature name for the object to be synchronized, 3rd %s: |
|
|
| unlicensed or license expired. |
|
| 691 |