Chapter 44 Service Control
3The CLI screen displays next.
44.8Telnet
You can use Telnet to access the ZyWALL’s command line interface. Specify which zones allow Telnet access and from which IP address the access can come.
44.8.1 Configuring Telnet
Click System > TELNET to configure your ZyWALL for remote Telnet access. Use this screen to specify from which zones Telnet can be used to manage the ZyWALL. You can also specify from which IP addresses the access can come.
Figure 451 System > Telnet
The following table describes the labels in this screen.
Table 209 System > Telnet
LABEL | DESCRIPTION |
Enable | Select the check box to allow or disallow the computer with the IP address that |
| matches the IP address(es) in the Service Control table to access the ZyWALL |
| CLI using this service. |
|
|
Server Port | You may change the server port number for a service if needed, however you must |
| use the same port number in order to use that service for remote management. |
|
|
Service Control | This specifies from which computers you can access which ZyWALL zones. |
|
|
# | This the index number of the service control rule. |
|
|
Zone | This is the zone on the ZyWALL the user is allowed or denied to access. |
|
|
Address | This is the object name of the IP address(es) with which the computer is allowed or |
| denied to access. |
|
|
Action | This displays whether the computer with the IP address specified above can access |
| the ZyWALL zone(s) configured in the Zone field (Accept) or not (Deny). |
|
|
Add icon | Click the Add icon in the heading row to open a screen where you can add a new |
| rule. Refer to Table 207 on page 592 for information on the fields. |
| Click the Edit icon to go to the screen where you can edit the rule. |
| Click the Add icon in an entry to add a rule below the current entry. |
| Click the Delete icon to remove an existing rule. A window display asking you to |
| confirm that you want to delete the rule. Note that subsequent rules move up by one |
| when you take this action. |
| Click the Move to N icon to display a field to type a number for where you want to |
| put that rule and press [ENTER] to move the rule to the number that you typed. |
|
|
604 |
| |