Configuration - Screens and Control Fields

Control Fields on the Configuration Screens

Ext Ref In

This field selects the reference frequency of the signal at the EXT REF IN connector. You can select 1, 2, 5, or 10 MHz; 1x, 2x, 4x, 8x, or 16x chip.

Operating Considerations

This signal is used as a reference for, and directly affects, these functions:

RF Generator Frequency (including the Tracking Generator)

RF Frequency Counter

AF Frequency Counter

RF Analyzer Tune Frequency

Spectrum Analyzer Center Frequency

AF generators 1 and 2 are not affected by the external reference; they use their own reference.

See “EXT REF IN” on page 287 for more information.

FF at End

This field is used to specify if you want the printer to make a form feed (blank page) at the end of printing.

Screen(s) Where Field is Present

PRINTER CONFIGURE

FF at Start

This field is used to specify if you want the printer to make a form feed (blank page) at the start of printing.

Screen(s) Where Field is Present

PRINTER CONFIGURE

Firmware

This field displays the current firmware revision for your Test Set. The revision number is automatically changed when updated firmware is installed.

Screen(s) Where Field is Present

INSTRUMENT CONFIGURE

Chapter 7

233

Page 229
Image 229