CDMA Measurements - Screens and Control Fields

Control Fields for CDMA Measurements

Meas Order

This field is displayed in the Code Domain Analyzer, IS-2000. The Measurement Order is the way in which the Walsh channels are shown on the screen. Select Bit Reversed to show channels grouped according to their Walsh order. Select Hadamard to show channels grouped by channel number, as in the IS-95 standard.

Screens on which this field is present

CDMA ANALYZER

CODE DOM (Code Domain Analyzer, IS-2000 only): auxiliary controls menu

Measurement

This field controls the type of code domain measurement to make. In IS-95 only mode, this includes power, fast power, timing, or phase. In IS-2000 mode, this includes power, fast power, power and noise, complex power, and fast power synchronization.

It also controls the measurement mode (single or continuous):

Single is used when you want to make one measurement.You must select the Arm Meas function of the Analyzer field before a measurement can be made.

Cont is used to continuously make measurements. Measurements are automatically re-armed after each measurement.

Screens on which this field is present

COD DOM (Code Domain Analyzer): main controls menu

Num Avgs

The number of averages determines how many measurements are averaged when measuring fast power. Averaging reduces measurement speed.

Screens on which this field is present

COD DOM (Code Domain Analyzer): fast power setup controls menu

Chapter 5

163

Page 160
Image 160
Agilent Technologies 8935 series e6380a manual Meas Order, Measurement, Num Avgs