CDMA Measurements - Screens and Control Fields

CDMA Measurements

Figure 5-1

Rho

ρ=

ρ=

ρ>

Pow erthatcorrelatesw ith ideal TotalPow er

SignalPow er SignalPow er+ ErrorPow er

0.912

Screens on which this measurement is displayed

CDMA ANALYZER

CDMA GENERATOR

Estimated Rho (Est Rho)

Estimated rho is an calculated approximation of rho that is made without taking the base station out of service.

Screens on which this measurement is displayed

• CODE DOM (Code Domain Analyzer)

Frequency Error (Freq Err)

Frequency error is displayed when the Rho measurement is selected. Frequency error is the difference between the base station’s transmitter frequency and the frequency you enter in the Tune Freq field.

Screens on which this measurement is displayed

CDMA ANALYZER

CDMA GENERATOR

CODE DOM (Code Domain Analyzer)