Overview of theTest Set’s Built-In Tools

Using the RF Tools Program

Making the Measurement

1.Select Cable Fault from the Select Test (Main) Menu. The Cable Fault Information menu will appear.

Figure 4-16 Selecting the Cable Fault Measurement

Select Main Menu

Cable Fault Measurement

2.Position the cursor at Sweep center frequency (MHz) and select. A Choices menu appears.

505 MHz - Use this center frequency for high resolution, short range cable tests. The cable lengths can range from 10 to 1000 ft.

850 MHz - Use this center frequency for cable tests at cellular frequencies. This should be used for frequency sensitive devices, such as filters, and has a cable length range of 150 to 1000 ft.

1850 MHz - Use this center frequency for cable tests at PCS frequencies. This should also be used for frequency sensitive devices and has a cable length range of 150 to 1000 ft.

3.Position the cursor at Cable length and enter the appropriate value.

98

Chapter 4

C:\Spk\Ref\RefGuideRevE\Tools.fm

Page 96
Image 96
Agilent Technologies 8935 series e6380a manual Select Main Menu Cable Fault Measurement