Agilent Technologies 8935 series e6380a manual Send Dsat FVC, Send Filler Focc

Models: 8935 series e6380a

1 320
Download 320 pages 25.58 Kb
Page 270
Image 270

Signaling Encoder and Decoder - Screens and Control Fields

Control Fields for the Signaling Encoder and Decoder

Send

Selecting this field causes the FVC or FOCC message to be output.

Operating Considerations

When sending an FOCC message stream, the contents of the Filler are continuously output after the message data has been sent. Stop Filler is used to stop the output.

Screens Where Field is Present

SIGNALING ENCODER (Modes: AMPS-TACS, NAMP-NTAC, DTMF)

Send DSAT (FVC)

This field is available only in NAMP-NTAC mode.

Selecting this field causes the contents (24 bits) of the DSAT field to be continuously output until Stop DSAT is selected. If a message or DST is sent by selecting Send, the DSAT data is output continuously after the message is output.

Screens Where Field is Present

SIGNALING ENCODER (Modes: AMPS-TACS, NAMP-NTAC)

Send Filler (FOCC)

Selecting this field causes the contents of the Filler fields for Stream A and Stream B to be output. The fillers continue to be output until Stop Filler is selected.

Screens Where Field is Present

SIGNALING ENCODER (Modes: AMPS-TACS, NAMP-NTAC)

274

Chapter 8

C:\Spk\Ref\RefGuideRevE\Enc-dec.fm

Page 270
Image 270
Agilent Technologies 8935 series e6380a manual Send Dsat FVC, Send Filler Focc