Agilent Technologies 8935 series e6380a manual Waveform, Signaling Encoder Modes Dtmf

Models: 8935 series e6380a

1 320
Download 320 pages 25.58 Kb
Page 276
Image 276

Signaling Encoder and Decoder - Screens and Control Fields

Control Fields for the Signaling Encoder and Decoder

Example 8-6

Example 4:

3 kHz deviation, Twist 2.5 dB, Pre-emphasis on.

If sending a 1 (697 Hz low tone and 1209 Hz high tone), the high tone’s deviation is 1.334 (see “Example 2:” on page 279) ⋅ 1.735 (see “Example 3:” on page 279) approximately 2.314 times the low tone’s deviation.

Since the peak deviation of their sum is 3 kHz, the low tone’s deviation is 905.5 Hz and the high tone’s deviation is 2094.5 Hz.

Screens Where Field is Present

SIGNALING ENCODER (Modes: DTMF)

Waveform

This field selects the desired waveform for AF Generator 2. The available waveforms are as follows:

Sine wave

Square wave

Triangle wave

Ramp (positive-going and negative-going)

DC±

Universal Noise

Gaussian Noise

Screens Where Field is Present

SIGNALING ENCODER (Modes: Func Gen)

280