Chapter 4 Replacing Cisco 7201 Field-Replaceable Units

Removing and Installing a DC Power Supply

Figure 4-11 Locating the DC Grounding Stud and Grounding Materials

PWR SLOT 2

170970

Step 1 Locate the grounding stud on the DC power supply.

Step 2 Using the ground lugs from the previous power supply, replace them and the star washers and nut in the following order:

a.Star washer

b.Ground lug with ground wire

c.Star washer

d.Ground lug with ground wire

e.Nut

Note If you are using the new lugs that came with the new DC power supply, see the “Installing the DC Grounding Leads” section on page 2-27for instructions on wiring the ground lugs and ground wires.

Step 3 Tighten the nut to complete the installation.

To continue the DC power supply installation procedure, go to the “Wiring the DC-Input Power Source” section on page 4-13.

Wiring the DC-Input Power Source

Note The color coding of the DC-input power supply leads depends on the color coding of the DC power source at your site. Make certain the lead color coding you choose for the DC-input power supply matches lead color coding used at the DC power source.

Warning When you install the unit, the ground connection must always be made first and disconnected last.

Statement 1046

 

 

Cisco 7201 Installation and Configuration Guide

 

 

 

 

 

 

OL-11364-04

 

 

4-13

 

 

 

 

 