Chapter 3 Starting and Configuring the Router

Functional Overview

Reporting Functions

The Cisco 7201 router displays warning messages on the console if chassis interface-monitored parameters exceed a desired threshold. You can also retrieve and display environmental status reports with the show environment, show environment all, show environment last, and show environment table commands. Parameters are measured and reporting functions are updated every

60 seconds. A brief description of each of these commands follows.

Caution To prevent overheating the chassis, ensure that your system is drawing cool inlet air. Overtemperature conditions can occur if the system is drawing in the exhaust air of other equipment. Ensure adequate clearance around the sides of the chassis so that cooling air can flow through the chassis interior unimpeded and exhaust air exits the chassis and is not drawn into the inlet vent of another device.

The show environment command displays reports of the current environmental system status. The report displays parameters that are out of the normal values. No parameters are displayed if the system status is normal. The example that follows shows the display for a system in which all monitored parameters are within normal range:

Router# show environment

All measured values are normal

If the environmental status is not normal, the system reports the worst-case status level. Following is a sample overvoltage warning:

Router# show environment

Warning:+3.45 V measured at +3.27 V

The show environment last command retrieves and displays the NVRAM log, which shows the reason for the last system shutdown (if the shutdown was related to voltage or temperature) and the environmental status at that time. Air temperature is measured and displayed, and the DC voltage supplied by the power supply is also displayed.

Following is sample output of the show environment last command:

Router# show environment last

NPE Inlet

previously measured at 28C/82F

NPE Outlet

previously measured at 30C/86F

CPU Die

previously measured at 42C/107F

+3.30

V

previously measured at +3.24

+1.50

V

previously measured at +1.48

+2.50

V

previously measured at +2.46

+5.15

V

previously measured at +4.96

+1.20

V

previously measured at +1.17

VDD_CPU

previously measured at +1.25

-11.95

 

previously measured at -12.04

VTT

 

previously measured at +1.23

last shutdown reason - power supply shutdown 7201_creg6#

The show environment table command displays the temperature and voltage thresholds for each temperature sensor and for each monitored status level. These thresholds are related to those listed in Table 3-1and Table 3-2. The display also lists the shutdown threshold for the system.