Chapter 4 Replacing Cisco 7201 Field-Replaceable Units

Removing and Installing a DC Power Supply

Figure 4-10 Removing the Ground Lugs

PWR SLOT 2

170970

Caution The DC return connection to this system is to remain isolated from the system frame and chassis (DC-I).

Step 1 On the front of the router, turn the power switch to the standby () position.

Step 2 Switch the circuit breaker to the off position, and tape the switch handle to the off position. Step 3 Pull the terminal block plug from the terminal block.

Step 4 Locate the DC power supply grounding stud.

Step 5 Remove the nut, ground lug, star washer, ground lug, and star washer and save for reuse on the new DC power supply.

Step 6 Move the power up restrictor to the left to gain access to the upper power supply captive installation screw.

Step 7 Use a Number 2 Phillips screwdriver to unscrew the upper power supply captive installation screw. Step 8 Unscrew the lower power supply captive installation screw on the lower left of the power supply. Step 9 Grasping the captive installation screws, pull the power supply from the chassis.

This complete the procedure for removing the DC power supply.

Installing the DC Power Supply

Warning This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 120 VAC, 20A U.S. (240 VAC, 10A international). Statement 1005

Warning Never install an AC power module and a DC power module in the same chassis. Statement 1050

This section provides instructions for installing the DC power supply ground leads and installing the DC-input power leads.

 

 

Cisco 7201 Installation and Configuration Guide

 

 

 

 

 

 

OL-11364-04

 

 

4-11

 

 

 

 

 

Page 105
Image 105
Cisco Systems CISCO7201 manual Installing the DC Power Supply, Removing the Ground Lugs