Fluke PM6681R, PM6685R manual Speed Summary, Timesaving Com, Time Gain in ms, Sacrifice, mands

Models: PM6685 PM6685R PM6681 PM6681R

1 276
Download 276 pages 1.51 Kb
Page 113
Image 113
Timesaving Com-

 

 

 

 

How to Measure Fast

 

 

 

 

 

Timesaving Com-

Time Gain in ms

Sacrifice

mands

 

 

 

 

PM6680B

PM6681

PM6685

 

 

 

 

 

 

 

 

 

Freq

Freq

Freq

 

 

 

 

 

 

FREQ:RANG:LOW￿MAX

(23)

 

(23)

10kHz lower freq. limit for AUTO. This

 

 

 

 

 

 

 

Timesaving is only possible when

 

 

 

 

AUTO is on.

 

 

(55)

 

50kHz lower freq. limit for AUTO. This

 

 

 

 

 

 

 

 

Timesaving is only possible when

 

 

 

 

AUTO is on.

INP:LEV:AUTO￿OFF

40

70

52

You have to set trigger levels manually.

 

 

 

 

 

 

 

DISP:ENAB￿OFF

5.4

3.5

7.7

Only the controller can read the result.

 

 

 

 

 

 

 

CAL:INT:AUTO￿OFF

0.22

N.A.

0.22

You must instruct the counter to cali-

 

 

 

 

 

 

brate the interpolators once in a while

 

 

 

 

to maintain accuracy.

SENS:ACQ:RES￿LOW

0.81

0 / 0.1

0.81

Works up to about 40kHz. The resolu-

 

 

 

 

 

 

tion of each measurement drops to

 

 

 

 

100ns for PM6680B/85 and 80ns for

 

 

 

 

PM6681

 

 

 

 

(PM6681 Only: Gives Back-to-back

 

 

 

 

measurements in period, i.e. every pe-

 

 

 

 

riod in a block is measured)

TRIG:COUNT￿2100

0.69

N.A.

0.69

No sacrifice, the program loop in the

 

 

 

 

 

 

counter gets shorter, saving time.

TRIG:COUNT￿6143

N.A.

4.2

N.A.

 

 

 

 

 

 

 

 

INT:FORM￿PACK

1.15

1.2

1.15

You cannot use limit monitoring, math-

 

 

 

 

 

 

ematics etc. in the CALC subsystem,

 

 

 

 

nor the Display or the Output subsys-

 

 

 

 

tems.

TRIG:COUNT￿1000(o

N.A.

0.13

N.A.

These commands (all together) will in-

r more)

 

 

 

 

crease measurement speed the last

STAT:OPER:ENAB￿0

 

 

 

 

 

 

step from about 4000 to over 8000

ARM:STA:LAY2:SOUR

 

 

 

 

 

 

measurements/s

￿ IMM

 

 

 

INP:LEV:AUTO￿OFF

 

 

 

 

(All together)

 

 

 

 

FORM:TINF￿OFF

N.A.

0

N.A.

No timestamping possible. This only

 

 

 

 

 

 

influences the read. Time stamps are

 

 

 

 

always registred internally.

 

 

 

 

 

￿All these time gain estimates are approximations valid for frequency A mea- surements and may be changed without notice. The time gain/loss depends on measuring function.

Speed Summary 7-15