Appendix B

 

( SRS -2100 Installation

 

 

 

 

 

 

 

 

 

 

The maximum distance between

 

Two Unit Installations

the NT1 and the ISDN Terminal

 

Bridging at the NT1 – Distance

Equipment is 3000 feet in a single

 

 

Between NT1 and Units is Greater

unit installation. The TR switch

 

 

Than 250 ft.

on the Terminal Equipment

 

 

 

 

 

 

should be ON. The TR switches

 

The overall maximum length of the

on the NT1 should be set at On at

 

cable is 1600 ft. The TR switches

100 Ohms. NT1 timing should be

 

on both Terminal Equipment

set to ADAPTIVE (or PTP).

 

Units should be ON. The TR

NT1 (TR = 100 Ohms)

 

switched on the NT1 should be

 

set to OFF. NT1 timing switches

 

 

 

 

 

 

 

 

 

 

Terminal Equipment (TR = O

 

(if present) should be set to

 

 

 

 

 

 

 

 

 

 

FIXED or (PB) when the distance

Two Unit Installations

 

between the NT1 and the

 

Terminal Equipment is 400 ft or

Bridging at the NT1 – Maximum

 

 

less for level 3 wire, or 600 ft for

Distance Between NT1 and Units

 

 

level 5 wire. Longer loops require

is 250 ft.

 

 

ADAPTIVE (or PTP).

 

 

 

 

 

 

The overall maximum length of the

 

NT1 (TR = OFF)

 

 

 

 

 

cable is 1600 ft. The TR switch on

 

 

 

 

Terminal Equipment (TR = ON)

 

 

 

 

both Terminal Equipment Units

 

 

 

 

Terminal Equipment (TR = ON)

 

 

 

 

should be OFF. The TR switches

 

Multiple Unit Installations –

on the NT1 should be set to ON

 

 

Bridging at the NT1

at 50 Ohms. NT1 timing switches

 

 

 

 

 

 

(if present) should be set to

 

The overall maximum length of the

FIXED or (PB).

 

cable is 1600 ft. The TR switch on

NT1 (TR = 50 Ohms)

 

the Terminal Equipment farthest

 

from the NT1 should be ON. The

 

 

 

Terminal Equipment (TR = OFF)

 

TR switches on all other Terminal

 

 

 

 

 

 

Terminal Equipment (TR = OFF)

 

Equipment should be OFF. The

 

 

 

 

 

 

 

 

 

TR switches on the NT1 should

 

 

 

 

 

 

be set to ON at 100 Ohms. NT1

 

 

 

 

 

 

timing switches (if present)

 

 

 

 

 

 

should be set to ADAPTIVE (or

 

 

 

 

 

 

PTP).

 

 

 

 

 

NT1 (TR = ON 100 Ohms)

 

 

 

 

 

 

 

 

Terminal Equipment (TR = OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Equipment (TR = OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Equipment (TR = ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page B-25

Page 144
Image 144
Fujitsu SRS-2100 manual Two Unit Installations, Bridging at the NT1 Distance, Bridging at the NT1 Maximum