SRS | Appendix C |
The following sections summarize the
LED Test
The LED test is done first automatically. It turns all but the data LEDs red for one second, off for one second, green for one second (except MSG), and finally off again. Observe the LEDs for malfunctions.
When the LED test is complete, you can start any of these tests:
∙Press 1 to start the Tone test.
∙Press 2 or 3 to start the LCD tests.
∙Press 4 to start the Memory/Line test.
∙Press 5 to start the Program and Loop switch test (with optional data terminal adapter only).
These tests are described in the sections below. Tests 1, 2, 3, and 5 can be started and interrupted at will to change the test under way, but test 4 cannot be interrupted by pressing any key.
Key Test
Pressing any button other than 1 through 5 sounds its associated confirmation or DTMF tone, turns its LED red (if it has one), and displays the following information on the LCD:
For the keys:
Soft keys
Service key Multifunction buttons Fixed function buttons
DTMF keypad keys
This information is displayed:
SOFTWARE Key X
SERVICE
MULTIASSIGN KEY nn
FUNCTION KEY 1 FUNCTION KEY 2 FUNCTION KEY 3 FUNCTION KEY 4 FUNCTION KEY 5 FUNCTION KEY 6
TEN KEY X
With the range and meaning shown here:
X=1:SOFT1 2:SOFT2 3:SOFT3 4:SOFT4
Service key
nn: 1 to 30 (key no.)
DROP1
TRANSFER1
HOLD
CONFERENCE1
REDIAL
SPEAKER
1Recommended user assignme nt
X=(5), 6, 7, 8, 9, 0, #, and *