Environmental specifications

Environmental specifications

The following specifications identify maximum environmental conditions. At no time should the server run under conditions which violate these specifications.

Variable

Requirements

Temperature

Maximum rate of change: 18°F (10°C) per hour

 

Nonoperating: -55° to 150°F (-48.3° to 65.5°C)

 

Operating: 41° to 95°F (5° to 35°C); derated 0.9°F (0.5°C) for every

 

1,000 feet (305 meters)

Altitude

Humidity

10,000 feet (3,048 meters) maximum

Operating wet bulb: Not to exceed 91.4°F (33 °C) (with diskette drive or hard drive)

Nonoperating: 95% relative (noncondensing) at 86° F (30° C)

Shock

Operating: 2.0 g, 11 msec, ½ sine

 

Packaged: Operational after 30-inch free fall (cosmetic damage might

 

occur)

AC input power

100-240 V, 8.0 A, 50/60 Hz