Table 4-3

(Page

12

of

13). Firmware Checkpoints

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Checkpoint

 

Description

 

 

 

Repair

 

Action

 

 

 

(hex)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E206

 

Look

for

PRISM

on

1.

Replace

System

Planar

 

 

PCG

and

switch

to

 

 

 

 

 

 

 

 

50MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E207

 

Setup

 

Data

gather

1.

Replace

System

Planar

 

 

mode and 64/32-bit

 

 

 

 

 

 

 

 

mode

on

PCG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E208

 

Assign

bus

number

1.

Replace

System

Planar

 

 

on

PCG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E209

 

Assign

PCI

I/O

1.

Replace

System

Planar

 

 

addresses

on

PCI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E20A

 

Assign

PCI

I/O

1.

Replace

System

Planar

 

 

addresses

on

PCG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E20B

 

Check

 

MCERs

stuck

1.

Replace

System

Card

 

 

at

fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E20C

 

Testing

 

L2

cache

1.

Replace

CPU

Card

 

 

 

 

 

 

 

 

 

E210

 

Processors

L1

data 1.

Replace

System

Planar

 

 

cache

array

test

 

 

 

 

 

 

 

 

fails.

System

Hangs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E211

 

IPL

ROS

CRC

 

1.

Replace

System

Planar

 

 

checking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E212

 

Processor POST

 

1.

Replace

CPU

Card

 

 

 

 

 

 

E213

 

Initial

memory

 

See “MAP 1240: Memory Problem Resolution” on

 

 

configuration

 

page

2-12

 

 

 

 

 

 

 

 

 

E214

 

Memory

test

 

See “MAP 1240: Memory Problem Resolution” on

 

 

 

 

 

 

 

 

 

page

2-12

 

 

 

 

 

 

 

 

 

 

 

 

 

E216

 

Copy

ROS

into

 

1.

Replace

Memory

Card

 

 

RAM.

Setup

 

 

 

 

 

 

 

 

 

 

Translation

and

C

 

 

 

 

 

 

 

 

environment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E21A

 

System

has

some

1.

See “Unresolved

problems” on page 4-26

 

 

good

memory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E220

 

Final

memory

 

 

See “MAP 1240: Memory Problem Resolution” on

 

 

configuration

 

page

2-12

 

 

 

 

 

 

 

 

 

 

 

 

 

E240

 

Setup

 

Winbond

ISA

1.

Replace

System

Planar

 

 

bridge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E241

 

Reset

PCI

Bus

1.

Replace

System

Planar

 

 

 

 

 

 

 

 

 

E242

 

Initialize

ISA

DMA

1.

Replace

System

Planar

 

 

channel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-247043 43P Series Service Guide

Page 136
Image 136
IBM SA38-0512-03 manual Prism, Pcg, Ipl, Crc