Firmware Error Codes

If you replace FRUs and the problem is still not corrected, go to MAP 0030 in the Diagnostics Information for Multiple BusunlessSy temsotherwise indicated in the

tables.

Table

3-2

(Page

1 of

9). Firmware Error Codes.

Error

Code

Description

Action/

 

 

 

 

Possible Failing FRU

 

 

 

 

20100xxx

Power

Supply

 

 

 

20A80xxx

Remote initial program load (RIPL)

 

 

error

 

 

 

 

 

xxx=000

Insufficient

information to boot.Verify the IP address.

001Client IP address is already inChanguse IPby address. other network device

002Cannot get gateway IP address Refer to “Firmware Checkpoints” on page 3-14 table usingF74 code.

003Cannot get server hardware addressRefer to “Firmware Checkpoints” on page 3-14 table usingF74 code.

004

Bootp

failed

 

 

Refer to “Firmware Checkpoints” on

 

 

 

 

 

page 3-14

table

usingF75

code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

005

File

transmission

(TFTP) failed

Check

 

network

connection,

try

again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20D00xxx

Unknown/Unrecognized device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

xxx=00F

Self-test failed on device, no

Check

 

the

System

Management

 

 

 

 

SRN/location code

information

availableServices

error

log

entry (if

 

present) for

 

 

 

 

 

the

location

code

of

the

failing device.

 

 

 

 

 

The

error

log

is

described

in “Step

 

 

 

 

 

1020-4”

on page 2-11

 

 

 

 

 

 

 

 

 

If the error code specifies a network

 

 

 

 

 

adapter, see 3-1.

 

 

 

 

 

 

 

 

 

010

Self-test failed on device, can'tContalocateyour service support

 

 

 

package.

 

 

representative

for

assistance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20E00xxx

Security

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

xxx=000

Power on Password entry error.

Retry

installing

the

password.

 

 

 

 

 

 

 

001

Privileged-access password entry

Retryor. installing the password.

 

 

 

 

 

 

 

 

002

Privileged-access

password

jumper Thenot privileged-access password

 

jumper

 

enabled.

 

 

is not in the correct position for

 

 

 

 

 

password

 

initial

entry.

 

 

 

 

 

 

 

 

 

Consult the system's User's Guide for

 

 

 

 

 

jumper

location

and

position.

 

 

 

3-47043 43P Series Service Guide

Page 94
Image 94
IBM SA38-0512-03 manual Firmware Error Codes, Description Action Possible Failing FRU