SCSI | Bus | Termination |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
The | Model | 140 | and Model 240 have a | fast/wide |
| |||||||||||||||
internal | and | external | SCSI | devices. However, each | controller | on these | SCSI | busses |
| |||||||||||
must have a unique SCSI id, and the | SCSI busses must be properly terminated both | |||||||||||||||||||
internally | and | externally (if | external | devices | are used) to ensure SCSI | signal | integrity. | |||||||||||||
For | directions | on | setting | the | SCSI | id | on | each | device, consult | the | documentation | for | ||||||||
that | device, | as | wellAdapters,as the Devices, | and | Cable | Information for | Multiple | Bus |
| |||||||||||
Systems . |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Model | 140 | Internal | SCSI | Bus | Termination |
|
|
|
|
|
|
|
|
|
|
|
| |||
The | Model | 140 | internal | SCSI | chain | must | be terminated by the last drive in the chain, | |||||||||||||
which | must | be | configured as a | drive | by | setting jumpers | on the | drive. | ||||||||||||
Please | consult | the | documentation that | came | with | your | SCSI | device. |
|
|
|
Note: Only the last drive in each SCSI chain should be configured as
External SCSI chains must be terminated by a separate SCSI terminator.
Power Cables
To avoid electrical shock, a power cable with a grounded attachment plug is provided. Use only properly grounded outlets.
Power cables used in the United States and Canada are listed by Underwriter's Laboratories (UL) and certified by the Canadian Standards Association (CSA).
These power cords consist of:
Ÿ Electrical cables, Type SVT or SJT.
ŸAttachment plugs complying with National Electrical Manufacturers Association (NEMA)
"For | 115 V | operation, | use a UL listed cable | set consisting | of | a | minimum | 18 | AWG, | ||||||
Type SVT or SJT | a maximum of 15 feet in | length | and | a parallel | |||||||||||
blade, | grounding type | attachment | plug | rated at 15 A, 125 V." |
|
|
|
|
|
| |||||
"For | 230 | V | operation | in the | United | States use a UL listed | cable | set | consisting of a | ||||||
minimum 18 AWG, Type SVT or SJT | cable | a maximum | of | 15 | feet | in |
| ||||||||
length, and | a tandem | blade, | grounding | type attachment | plug rated | at | 15 | A, | 250 | V." |
ŸAppliance couplers complying with International Electrotechnical Commission (IEC) Standard 320, Sheet C13.